See details at the bottom
of the page
|
 |
| Get complete Code compliant
solutions to electrical problems |
| Reduce errors and prevent
rework |
| Extensive problem solutions.
. . wire sizing, voltage drops, conduit sizes, motor full-load amps, parallel
and derated wire sizing, fuse and breaker sizes, overload protection sizing,
NEMA starter sizing, and much more |
| Fast, Easy-to-Use, Flexible.
. . Calculator works in terms and values specific to electrical applications |
| Factory updatable for
future years code revisions |
|
|
ElectriCalc
Pro Specifications
|
| SIZE: |
| 5.5" x 2.9" x 0.5" (140
mm x 74 mm x 13 mm) |
|
| WEIGHT: |
| 3.2 oz. (91 gm) - does not
include Vinyl Case or User's Guide |
|
| POWER: |
| Single 3-volt (CR-2032)
Long-life Lithium Battery |
|
| DISPLAY: |
| 8 Digits with Full Annunciators |
|
| LCD DIMENSIONS: |
| 0.563" x 2.25" (14 mm x
57 mm) |
|
| ACCURACY: |
| 10 Digit Internal Accuracy |
|
| INCLUDED WITH EVERY
PRODUCT: |
| Easy-to-Understand User's
Guide |
| Protective Carrying Case |
| Long-life Batteries |
|
| ONE YEAR WARRANTY: |
| All Calculated Industries
calculators and electronic tools are covered by a Full One-Year Limited
Warranty against defects in materials and workmanship. The full text of
each warranty is published in the documentation accompanying each product
and at www.calculated.com. Calculated Industries reserves the right to
make changes in the materials and specifications of products without notice.
|
|
|
|
|
CONSTRUCTION-MATH
"POWER TOOLS" TM
|
|
The Ultimate in
convenience, Versatility
|
|
ELECTRICALC®
PRO
|
Electrical
Code Calculator
Compliant with 2005, 2002, 1999, 1996 NEC®
|
Electrical Contractors
· Designers · Engineers · Electricians · Maintenance
Millwrights · Inspectors
· Planners · Builders · Lighting Specialists
|
|
|
The
ElectriCalc Pro is the world's most complete Code based electrical
calculator. It solves electrical calculations in seconds and delivers those
solutions in conformance to current Code. It's a complete electrical reference
tool that will save time, trouble and money. Now,
factory updatable for future code revisions!
Includes Armadillo Gear? protective Hard
Case.
It helps you solve for:
- Wire Sizes
- Integrated Voltage Drop
- Conduit Sizing
- Motor Full-Load Amps
- Fuse and Breaker Sizes
- NEC® Table Number displayed when
performing Wire Size calculations
- Service and Equipment Grounding Conductor
Sizes
- Enter BTU to find Kilowatts per Hour
- Enter Kilowatts per Hour to find BTU
Parallel Resistance
- Ohm?s Law Calculations ? enter any two
values to solve for the third
- Circular MILS wire sizes
|
| Calculates Wire Sizes
per NEC® 310-16 and 310-17 |
| Copper or aluminum, 3Ø/1Ø,
60°C, 75°C, 90°C insulation ratings at 100% or 125% of ampacity.
Adjusts wire sizes for ambient temperatures other than 30°C and for
more than three wires in a raceway. |
| Integrated Voltage Drop
Solutions |
| Let you find: Minimum VD
wire size, maximum length for any given wire size and drop percentage,
actual number and percentage of volts dropped. |
| Conduit Sizing for 12
Types of Conduit |
| Per 1999 NEC®
Table C1-C12, allows sizing of all common conduits for any combination
of #THW, #XHHW and #THHN wires. Plus, gives fill percentages, cross-sectional
areas, remaining areas and more. |
|
|
See details at the bottom of the page
|
- Work directly in and convert between Amps,
Watts, Volts, Volt-Amps, kVA, kW, PF% and EFF% and DC Resistance
- Calculate wire sizes per NEC® 310-16 and
310-17; Copper or aluminum, 3Ø/1Ø, 60°C, 75°C, 90°C insulation
ratings and 100% or 125% of ampacity. Adjust wire sizes for ambient
temperatures other than 30◦ C and for more than three wires in a
raceway
- Integrated voltage drop solutions.
Find minimum VD wire size, maximum Length for any given wire size, drop
percentage, actual number and percentage of Volts dropped
- Conduit sizing for 12 types of conduit.
Per 2005 NEC® Table C1-C12, find sizing of all common conduits for any
combination for #THW, #XHHW and # THHN wires. Plus, gives fill
percentages, cross-sectional areas, remaining areas and more
- Find Motor Full-Load Amps per Current NEC®.
Works in 1Ø and 3Ø with the new expanded tables for 3Ø induction (to
500 hp) synchronous (to 200 hp) and DC motors per NEC® 430-247, 430- 248
and 430-250.
- Calculates Fuse and Breaker Sizes.
Solves fuse and breaker sizes per NEC® 430-52
- Parallel and derated wire sizing
Parallel Resistance
- NEC Table number Displays when performing
Wire Sizes calculations
Sizes overload protection per NEC® 430-32
- Automatically finds NEMA starter sizes.
- Calculates service and equipment grounding
conductor sizes per NEC® 250-122 and 250-66; plus works directly in
electrical terms.
- Enter BTU to find Kilowatts per Hour
- Enter Kilowatts per Hour to find BTU
- Ohm?s Law Calculations ? enter any two
values to solve for the third.
- Circular MILS wire sizes
Additional
Features:
- Works as Standard Math Calculator with +, -,
x, ÷, +/-, %, Π, 1/x, X2, and √.
- Auto Shut-Off extends battery Life, Memory
- Update to future code revisions with
easy-to-install kit.
Inlcudes:
- Long-Life Battery
- Easy-to-follow User?s Guide
- Handy Pocket Reference Guide
- Ergonomically designed, Armadillo Gear® 360°
flip-top cover protective case
|
Size:
5.6? x 3.0? x 0.6? (142.8mm x 76.2mm x 15.9mm)
Product Weight (Including
Armadillo Gear Protective Hard Case and Pocket Reference Guide):
4.5 oz. (127.5 gm)
Power:
One 3-volt (CR-2032) Long-life Battery Included
Display Type:
LCD segment; 8 digits, with annunciator-legends
Display Dimensions:
0.625? x 2.5? (15.88 mm x 63.5 mm)
Accuracy:
10 Digit Internal Accuracy |
|
FAST...ACCURATE...EASY-TO-USE!
$99.95
|
| Look how simple solving
electrical math problems can be . . . |
| Finding Wire Size.
What size wiring is needed for a 240 volt, 125 amp, three phase system
if you are using 75°C copper wire? |
|
|
STEP
|
KEYSTROKE
|
DISPLAY SHOWS
|
| Reset
calculator |
[Set]
[x] |
0. |
| Set to
3-phase |
[Set]
3 |
3 PH |
| Set to
75°C |
[Set]
7 |
3 PH |
| Enter
amps |
125 [Amps] |
125. AMPS |
| Enter
volts |
240 [Volts] |
240. VOLT |
| Find wire
size |
[WireSz] |
1 CU
AWG |
|
|
|
|
---
Do
NOT Clear Calculator ---
|
| Finding voltage drop
wire size. (Continuing with above example) Assume load is moved
250 feet away and allowing for a 3% voltage drop, what is voltage drop
wire size? |
|
|
STEP
|
KEYSTROKE
|
DISPLAY SHOWS
|
| Enter
distance |
250 [length] |
250. FEET |
| Enter
allowable VD% |
3 [VD%] |
3.0 DROP
V% |
| Find wire
size |
[WireSz] |
0 CU
AWG VD WIRE SIZE |
| Find actual
voltage drop |
[VD%] |
6.6
V DROP |
| Find %
of voltage drop |
[VD%] |
2.8
V % DROP |
|
|
|
|
$99.95
| Finding conduit sizes
for multiple conductors. (Same wire tye and size) Find the minimum
IMC conduit size for nine #6 TWH copper wires. |
|
|
STEP
|
KEYSTROKE
|
DISPLAY SHOWS
|
| Clear
calculator |
[On/C]
[On/C] |
0. |
| Enter
conduit type |
4 [Set]
[CondSz] |
nonE IMC
COND |
| Enter
Wire Size |
6 [WireSz] |
6 CU AWG
WIRE SIZE |
| Enter
number & type of wire |
9 [#THW] |
9. THW
WIRES |
| Find conduit
size |
[CondSz] |
1.25
in IMC COND SIZE |
|
|
|
| The ElectriCalc Pro Electrical
Code Calculator is also available in a package with the 2002 Electronic
NEC Handbook.... Both products just $269.95! Click
here to learn more about this special offer. |
 |
|
|
ElectriCalc®
Pro Electrical Code Calculator - $99.95 each
|
|
|
|