P-SIM 2000 SPECIFICATIONS
ps1main.jpg (22922 bytes)
HARDWARE SPECIFICATIONS:
Industrial Device Panel: Not Required.
Using a standard Minimum IBM-486 DX33 or compatible Desk or Laptop computer, using Windows 3.1 or higher, industry standard electrical switching and motor control components are emulated in the 'P-SIM 2000' software.
This program comes complete with an exercise manual, containing over 200 electrical schematics and a windows program to view th corresponding Ladder Logic Diagram. To view example of the Exercise Manual, click on the link below. Exercise Manual Example
Programmable Controller: Not Required for Basic and Intermediate Level Training.
Complete functional operation of an industry standard Programmable Ladder Logic Controller is accurately emulated by the 'P-SIM 2000' software running on a standard IBM-486 or compatible computer. The internal Ladder Rung Editor closely resembles that of an A-B PLC and the multitasking program scan accurately emulates the typical on-line A-B program scan sequence.
For Advanced Manufacturer Specific Training.
Using the optional P-SIM I/O interface card which is mounted at and powered by the PLC, any make of Programmable Controller offering a minimum of 8 Input and 8 Output of 24VDC I/O can be easily linked to the user's desk or laptop computer (Visual Output Industrial Process Control Indicator) via standard RS232 serial cabling.
Visual Output Industrial Process Control Indicator:
Using a standard IBM 486 or compatible computer with VGA display, the P-SIM 2000 software provides dynamic simulation of typical Industrial processes in multicolor real-time display.
Simulated Processes respond accurately and in real-time to the Input and Output states of either the Integral (software emulated) PLC or optionally to an external serial linked (RS232) PLC.
The optional P-SIM I/O interface card connects to the 24VDC I/O cards of a standard PLC and converts these digital I/O signals to a serial format allowing connection to the Standard RS232 serial port of the user's desk or laptop computer.
IBM Interface for Process Modules: Not Required.
The P-SIM 2000 system is designed to work with the client's standard desktop or laptop computers without the need to have special interface or hardware cards installed. Optional connection to an external PLC is readily made using standard RS232 serial cabling allowing the use of highly portable Laptop computers for remote or off-site training sessions.
SOFTWARE SPECIFICATIONS:
Advanced Programming Software: Optional - Purchased with selected Programmable Controller.
Industrial Applications Software (Simulations):
 The P-SIM 2000 software includes the following simulated processes:
(1) Automated filling system
  • Operator Station Panel and controls
  • Conveyor with position sensors (photo switch)
  • Hopper with motorized chute control
  • Product Level Sensor
  • Conveyor Motor
  • Visual PLC Data Table Display including timers and counters
  • (2) Batch Mixing system Simulation
  • Operator Control Panel
  • 2 filler pumps and piping
  • 2 flow meters on filler lines
  • 1 mixing motor
  • 1 high level sensor
  • 1 low level sensor
  • 1 gas fired heater (controlled valve)
  • 1 temperature sensor
  • 1 discharge pump
  • 1 discharge flow meter
  • 1 Visual PLC Data Table display including timers and counters
  • (3) Intersection Traffic Light Control Simulation
  • 2-way traffic lights system
  • 4 Green Lights
  • 4 Red Lights
  • 4 Amber Lights
  • Visual PLC Data Table Display including timers and counters
  • 2 way traffic flow
  • (4) Hardware Input and Output Simulator
  • 4 toggle switches
  • 2 momentary normally open switches
  • 2 momentary normally closed switches
  • 8 controllable lights

  • Visual PLC Data Table Display including timers and counters
    PLC Emulation software (a P-SIM 2000 exclusive feature):
    The P-SIM 2000 software includes a full-featured built-in PLC Emulator package which runs concurrently on the same computer with the Industrial applications software (simulations) described above. With a single click of the mouse, the student may toggle back and forth between the display of the animated process simulation or the Ladder Rung Program Editor of the emulated PLC. The Program Editor is both user friendly and full-featured. Students may add, delete and modify program-rungs, branches  and instructions using simple menu selections.
    4 Input and Output branches supported 
    To test the new or modified ladder program, a single click of the mouse toggles the student back to the Process Simulation screen and places the PLC in the 'Run' mode. The process simulation will then react accurately to the student's newly programmed rungs which are constantly being scanned in the background by the PLC run-time emulator.
    By incorporating the Editor and run-time scanning of a PLC into software capable of running and interacting with the industrial process simulations, P-SIM 2000 provides a single computer hi-tech solution to Programmable controller student training, whether running on the network of a computer Lab, or on a student's own laptop computer. The P-SIM 2000 system allows a simple low-cost solution to PLC training while attaining superior student concept retention.
    I/O Graphics
    Student Record Disk, Manual and Instructor's Guide:
    Both the P-SIM 2000 and P-SIM 1000 programs come complete with 1 student disk and manual for the number of stations ordered, I.E. "(1 station) (5 station)." See pricing page for the number of stations available. The disk can be used to record the student's progress and stores the ladder logic programs developed by the student for all simulations and Lab exercises. The disk can also be used by the instructor to administer the programs.
    Return to P-SIM 2000
     
    © Copyright 2008 Maintenance Resources, Inc.
    Phone: 812.877.7119  -  Fax: 812.877.7116  -  E-Mail: info@maintenanceresources.com