Impeller
Diffuser Pump
|
|
| This is a still representation
and possibly also a low-resolution image of a fully animated pump. |
|
The efficiency of the Impeller Pump can be greatly increased by the addition
of stationary Diffuser Vanes. Large Impeller-diffuser pumps can achieve
efficiency ratings of 90 percent. |
|
The number of diffuser vanes is always different than the number of impeller
vanes. This is so that the edges of the rotating impeller vanes do not
come close to all the ends of the diffuser vanes at the same time |
|
This prevents thumping or knocking, and excessive buildup of pressures. |
|
In this drawing the innermost set of vanes revolves and the outer set is
stationary. |
|
© Copyright
2000 Maintenance Resources, Inc.
|
|
Phone: 812.877.7119
- Fax: 812.877.7116 - E-Mail: info@maintenanceresources.com
|
|
Address: 1983 North Hunt
Street - Terre Haute, IN 47805
|
|